[1]WANG Wei-shu,SHAGN GUAN Shan-shan,LU Tong,et al.Design of Splitters in Flue of SCR System for a 6U Mw Coal-fired Boiler[J].Journal of Zhengzhou University (Engineering Science),2015,36(04):37-40.[doi:10.3969/ j.issn.1671 -6833.2015.04.009]
Copy
Journal of Zhengzhou University (Engineering Science)[ISSN
1671-6833/CN
41-1339/T] Volume:
36
Number of periods:
2015 04
Page number:
37-40
Column:
Public date:
2015-08-31
- Title:
-
Design of Splitters in Flue of SCR System for a 6U Mw Coal-fired Boiler
- Author(s):
-
WANG Wei-shu1; SHAGN GUAN Shan-shan1; LU Tong1 ; YANG Zhi-feng2 ; ZHENG Chun-xiong1; CHEN Gang1
-
1.Institute of Thermal Engineering,North China University of Water Resources and Electric Power ,Zhengzhou 4500011, Chi-na; 2. Datang Anyang Power Generation Co. Ld,Anyang 455004, China ; 3.Shenzhen Yueneng Environmental Renewable Co.Ltd ,Shenzhen 518111 ,China
-
- Keywords:
-
SCR; flow field ; splitters; optimization
- CLC:
-
-
- DOI:
-
10.3969/ j.issn.1671 -6833.2015.04.009
- Abstract:
-
Based on FLUENT6.3 software,the simulation and analysis were applied to the optimization designof splitters in Selective Catalytic Reduction ( SCR ) denitrification system for a 600MW coal-fired boiler. Theresults show that because of variable cross-section and deflection in flue,flow field in the system appears non-uniform severely when there is no splitters. The velocity difference on two sides of the section at AlG lowerreaches is up to 15 m/s,the velocity deviations in the reactor inlet is 31.25% , and the flow field is poor intail flue,which affects the operation of downstream equipments.Reasonable splitters can improve flow field influe effectively. After equipping the transition pipe of the inlet with two group of longitudinal splitters, the ve-locity deviations in section at AIG lower reaches is reduced to 15% and in the reactor inlet is reduced to 13% .Splitters in elbow is equipped with an extension for guiding,which have a good effect on homogenization of thedownstream flow field.