[1]QI Ge,BAI Zuo-xia,LIU Xian-lin,et al.Analysis Of One-Phase Short-Circuit Performances of Dual Three-PhasePermanent Magnet Brushless Ac Motor[J].Journal of Zhengzhou University (Engineering Science),2015,36(01):28-32.[doi:10.3969/j.issn.1671-6833.2015.01.007]
Copy
Journal of Zhengzhou University (Engineering Science)[ISSN
1671-6833/CN
41-1339/T] Volume:
36
Number of periods:
2015 01
Page number:
28-32
Column:
Public date:
2015-01-10
- Title:
-
Analysis Of One-Phase Short-Circuit Performances of Dual Three-PhasePermanent Magnet Brushless Ac Motor
- Author(s):
-
QI Ge; BAI Zuo-xia; LIU Xian-lin; SHI Li
-
School of Electrical Engineering,Zhengzhou University,Zhengzhou 450001,China
-
- Keywords:
-
dual three-phase; permanent magnet machine; fault-tolerant performance; one-phase short-circuit
- CLC:
-
TQ523.59
- DOI:
-
10.3969/j.issn.1671-6833.2015.01.007
- Abstract:
-
The electromagnetic performance of the electromagnetic field distribution,flux linkage,current,and output torque and so on are analyzed,when dual three-phase motor is in fault condition of short-circuit ofone phase winding. At the same time,it is compared with traditional three-phase motor. Results indicate thatcoupling between phases of dual three-phase motor is very weak. In fault condition,the fault phase of dualthree-phase motor dose not affect normal operation of non-fault phase which makes it can still continue to workwithin the acceptable range. So dual three-phase motor does not have to stop on the way,and has a certain tol-erance,and is applicable to the occasion which has special requirements for motor.