[1]Tanaka,Stone Charter,Shen Changyu,et al.Injection cooling pipe network data processing[J].Journal of Zhengzhou University (Engineering Science),2007,28(03):105-108.[doi:10.3969/j.issn.1671-6833.2007.03.028]
Copy
Journal of Zhengzhou University (Engineering Science)[ISSN
1671-6833/CN
41-1339/T] Volume:
28
Number of periods:
2007年03期
Page number:
105-108
Column:
Public date:
1900-01-01
- Title:
-
Injection cooling pipe network data processing
- Author(s):
-
Tanaka; Stone Charter; Shen Changyu; etc
-
-
- Keywords:
-
- CLC:
-
-
- DOI:
-
10.3969/j.issn.1671-6833.2007.03.028
- Abstract:
-
The node-based pipe network analysis method is not suitable for special pipe networks containing nozzles and baffles, and the authors use splitting technology to convert the special pipe networks containing nozzles and baffles into ordinary pipe networks, which can be calculated by the nodal method. In further cooling analysis, because the more advanced cooling analysis model treats the coolant temperature as a constant, the temperature results on the pipe network cannot be used directly, and must be corrected and homogenized, and the concept of pipeline in-access and out-of-line degree is proposed, according to which each pipe section of the pipe network can be corrected and homogenized along the direction of coolant flow, and good results can be achieved.