[1]Yang Weizhong,Calculation of static intensity of the static intensity of the pressure -type steel ribs in the ribs[J].Journal of Zhengzhou University (Engineering Science),1993,14(04):107-116.
                                
                                Copy
                                
                                
                             
                            
                                
                                    Journal of Zhengzhou University (Engineering Science)[ISSN
                                    1671-6833/CN
                                    41-1339/T] Volume:
                                    14
                                    Number of periods:
                                    1993 04
                                    Page number:
                                    107-116
                                    Column:
                                    
                                    Public date:
                                    1993-12-28
                                
                                
                                    - Title:
 
                                    - 
                                        Calculation of static intensity of the static intensity of the pressure -type steel ribs in the ribs
 
                                
                                
                                
                                    - Author(s):
 
                                    - 
                                        Yang Weizhong;
 
                                    - 
                                        The Department of Civil Construction of Zhengzhou Institute of Technology,
 
                                    - 
                                
 
                                
                                    - Keywords:
 
                                    - 
                                        Combination structure;  shear connector;  strength
 
                                
                                
                                    - CLC:
 
                                    - 
                                        -
 
                                
                                
                                    - DOI:
 
                                    - 
                                        -
 
                                
                                
                                
                                    - Abstract:
 
                                    - 
                                        This article starts with the launch test of the poured loading connector of the band -type steel plate, and puts forward a simplified calculation model. The equilibrium conditions export the static intensity calculation formula of the calculation of the computing part. This formula has the advantages of clear concepts and simple forms, and the test value and calculation value are very good.