[1]QI Ge,BAI Zuo-xia,LIU Xian-lin,et al.Analysis Of One-Phase Short-Circuit Performances of Dual Three-PhasePermanent Magnet Brushless Ac Motor[J].Journal of Zhengzhou University (Engineering Science),2015,36(01):24-27.[doi:10.3969/j.issn.1671-6833.2015.01.006]
                                
                                Copy
                                
                                
                             
                            
                                
                                    Journal of Zhengzhou University (Engineering Science)[ISSN
                                    1671-6833/CN
                                    41-1339/T] Volume:
                                    36
                                    Number of periods:
                                    2015 01
                                    Page number:
                                    24-27
                                    Column:
                                    
                                    Public date:
                                    2015-01-10
                                
                                
                                    - Title:
 
                                    - 
                                        Analysis Of One-Phase Short-Circuit Performances of Dual Three-PhasePermanent Magnet Brushless Ac Motor
 
                                
                                
                                
                                    - Author(s):
 
                                    - 
                                        QI Ge; BAI Zuo-xia; LIU Xian-lin; SHI Li
 
                                    - 
                                        dual three-phase;permanent magnet machine; fault-tolerant performance; one-phase short-cir-cuit
 
                                    - 
                                
 
                                
                                    - Keywords:
 
                                    - 
                                        dual three-phase;  permanent magnet machine;  fault-tolerant performance;  one-phase short-cir-cuit
 
                                
                                
                                    - CLC:
 
                                    - 
                                        TM351
 
                                
                                
                                    - DOI:
 
                                    - 
                                        10.3969/j.issn.1671-6833.2015.01.006
 
                                
                                
                                
                                    - Abstract:
 
                                    - 
                                        The electromagnetic performance of the electromagnetic field distribution,flux linkage,current,and output torque and so on are analyzed,when dual three-phase motor is in fault condition of short-circuit ofone phase winding. At the same time,it is compared with traditional three-phase motor. Results indicate thatcoupling between phases of dual three-phase motor is very weak. ln fault condition,the fault phase of dualthree-phase motor dose not affect normal operation of non-fault phase which makes it can still continue to workwithin the acceptable range. So dual three-phase motor does not have to stop on the way , and has a certain tol-erance,and is applicable to the occasion which has special requirements for motor.