[1]谷海华,任爱梅,詹予忠..电冰箱换热器以铝代铜腐蚀特性的实验研究[J].郑州大学学报(工学版),2012,33(03):84-86.[doi:10.3969/j.issn.1671-6833.2012.03.021]
 GU Haihua,REN Aimei,ZHAN Yuzhong.Experimental Study on the Corrosion Behaviour of Aluminium in Place ofCopper in Refrigerator Heat Exchanger[J].Journal of Zhengzhou University (Engineering Science),2012,33(03):84-86.[doi:10.3969/j.issn.1671-6833.2012.03.021]
点击复制

电冰箱换热器以铝代铜腐蚀特性的实验研究()
分享到:

《郑州大学学报(工学版)》[ISSN:1671-6833/CN:41-1339/T]

卷:
33
期数:
2012年03期
页码:
84-86
栏目:
出版日期:
2012-05-10

文章信息/Info

Title:
Experimental Study on the Corrosion Behaviour of Aluminium in Place ofCopper in Refrigerator Heat Exchanger
作者:
谷海华任爱梅詹予忠.
河南新飞电器有限公司,河南新乡,453002, 郑州大学 化工与能源学院,河南郑州,450001
Author(s):
GU HaihuaREN AimeiZHAN Yuzhong
1. Henan Xinfei Electrie Co, , Ld, Xinxiang 453002,China; 2. Sehool of Chemical and Energy Pngneenng,Zhengzhou University,Zhengzhou 450001.China
关键词:
换热器 以铝代铜 耐蚀性 电偶腐蚀
Keywords:
heat exchanger aluminum replacing copper corrosion resistance galvanie corrosion
分类号:
TG172.6
DOI:
10.3969/j.issn.1671-6833.2012.03.021
摘要:
通过T2纯铜和1060纯铝在R22制冷剂和5%的HCI、H2SO4、NaOH、NaCl溶液中的纯腐蚀和电偶腐蚀实验,比较了铜和铝的腐蚀特性.结果表明铜在各介质中腐蚀速度都相当低,表现出良好的耐蚀性,而铝在这5种介质中的纯腐蚀速度差别巨大.铝在制冷剂R22中表现出了与铜相似的耐蚀性,腐蚀速度只有0.041 mm·a-1.在NaCl中的腐蚀速度也较低,为0.063 mm·a-1.但在HCl和NaOH中腐蚀极严重.铜-铝电偶腐蚀结果表明铝被加速腐蚀,而铜的腐蚀过程受到抑制.铝可以代替铜作为冰箱换热器材料,但应进行必要的表面涂覆处理.
Abstract:
The corrosion behaviours of T2 copper and 1060 aluminum are compared via pure corrosion and gal.vanic corrosion test in R22 refrigerant and $% HCl, H,$O,, NaOH, and NaCl solution. The results show thatthe pure corrosion speed of copper in all these media is quite low, showing good corrosion resistance, mean.while the pure corrosion speed of aluminum in these media is of great difference, Aluminum in R22 refrigerantshows similar corrosion resistance to copper, and the corrosion speed is only 0. 041 mm a-1. The corrosionspeed in NaCl is 0. 063 mm · a-1. However, the corosion of aluminum in HCl and NaOH is catastrophie.T’he results of copper-aluminum galvanic corrosion show that the corrosion of aluminum is accelerated and thecorrosion of copper is inhibited. Aluminum can replace copper as refrigerator heat exchanger materials, butsurface coating treatment is necessary.

相似文献/References:

[1]谭国锋,王珂,王永庆,等.折流板安装角对扇叶型折流板换热器性能影响[J].郑州大学学报(工学版),2018,39(06):74.[doi:10.13705/j.issn.1671-6833.2018.03.011]
 Tan Guofeng,Wang Ke,Wang Yongqing,et al.Study on Performances of Blade Baffle Heat Exchanger with Different Baffle Installation Angles[J].Journal of Zhengzhou University (Engineering Science),2018,39(03):74.[doi:10.13705/j.issn.1671-6833.2018.03.011]
[2]王永庆,王芳芳,古新,等.缠绕螺纹管螺旋折流板换热器流动与传热数值分析[J].郑州大学学报(工学版),2019,40(04):16.[doi:10.13705/j.issn.1671-6833.2019.03.011]
 Wang Yongqing,Wang Fangfang,Old and new,et al.Analysis of shell side heat transfer mechanism under coupling spiral action[J].Journal of Zhengzhou University (Engineering Science),2019,40(03):16.[doi:10.13705/j.issn.1671-6833.2019.03.011]
[3]古新,刘冰,董其伍,等.三角形布管方式下两种换热器传热与流阻性能研究[J].郑州大学学报(工学版),2012,33(03):76.[doi:10.3969/j.issn.1671-6833.2012.03.019]
 GU Xin,LU Bing,DONG Qiwu,et al.Performance Investigation of Heat Transfer and Flow Resistance in Two Kinds ofHeat Exchangers of Tube Bundle Arrangement with Equilateral Triangles[J].Journal of Zhengzhou University (Engineering Science),2012,33(03):76.[doi:10.3969/j.issn.1671-6833.2012.03.019]
[4]王永庆,靳遵龙,郭晓迪,等.一种带状支撑的纵流壳程换热器热力特性分析[J].郑州大学学报(工学版),2013,34(04):77.[doi:10.3969/j.issn.1671-6833.2013.04.018]
 WANG Yong-qing,JIN Zun-long,GUO Xiao-di,et al.Analysis of Thermodynamic Characteristics in Shell Side of a Shell-and-tube Heat Exchanger with Ribbon Support[J].Journal of Zhengzhou University (Engineering Science),2013,34(03):77.[doi:10.3969/j.issn.1671-6833.2013.04.018]
[5]刘敏珊,董其伍,魏新利,等.用MFC开发换热设备零部件ARX应用程序[J].郑州大学学报(工学版),1999,20(02):1.[doi:10.3969/j.issn.1671-6833.1999.02.001]
 LIU Minshan,Dong Qiwu,WEI Xinli,et al.Developed ARX applications for heat exchanger components with MFC[J].Journal of Zhengzhou University (Engineering Science),1999,20(03):1.[doi:10.3969/j.issn.1671-6833.1999.02.001]
[6]王学生,董其伍,刘敏珊,等.新型 RRS 换热器的随机响应分析[J].郑州大学学报(工学版),1997,18(03):17.
 Wang student,Dong Qiwu,Liu Minshan,et al.Random response analysis of the new RRS heat exchanger[J].Journal of Zhengzhou University (Engineering Science),1997,18(03):17.
[7]董其伍,刘敏珊,郭茶秀,等.纵流壳程换热器性能研究[J].郑州大学学报(工学版),1996,17(03):1.
 Dong Qifu,Liu Minshan,Guo Chaxiu,et al.Research on the Performance of Performance of the Poor Shell[J].Journal of Zhengzhou University (Engineering Science),1996,17(03):1.
[8]刘敏珊,董其伍.列管换热器振动分析的传递矩阵法[J].郑州大学学报(工学版),1991,12(01):49.
 Liu Minshan,Dong Qiwu,The transmission matrix method of the vibration analysis of the tube switching device[J].Journal of Zhengzhou University (Engineering Science),1991,12(03):49.
[9]董其伍,刘敏珊.列管式换热器管板的应力分析[J].郑州大学学报(工学版),1989,10(01):69.
 [J].Journal of Zhengzhou University (Engineering Science),1989,10(03):69.

更新日期/Last Update: 1900-01-01