[1]孙丰奇.10KV、35KV线路保护组合继电器[J].郑州大学学报(工学版),1995,16(04):52-54.
 Sun Fengqi.10KV, 35KV line protection combination relay[J].Journal of Zhengzhou University (Engineering Science),1995,16(04):52-54.
点击复制

10KV、35KV线路保护组合继电器()
分享到:

《郑州大学学报(工学版)》[ISSN:1671-6833/CN:41-1339/T]

卷:
16
期数:
1995年04期
页码:
52-54
栏目:
出版日期:
1995-04-28

文章信息/Info

Title:
10KV, 35KV line protection combination relay
作者:
孙丰奇
郑州工学院
Author(s):
Sun Fengqi
Zhengzhou Institute of Technology
关键词:
集成电路电流速断保护过电流保护三相一次重合闸组合继电器
Keywords:
Integrated circuit current speed break protection over -current protection three phases once again closing the gate combining relay
文献标志码:
A
摘要:
“10KV、35KV线路保护组合继电器”是许昌继电器研究所委托我们研制的继电器新型式。该继电器采用集成电路构成,集线路的速断保护、过电流保护及三相一次重合闸于一体。本文介绍组合继电器的构成原理。
Abstract:
"10kv, 35kv line protection group relay" is a new type of relay developed by the Xuchang Research Institute. The relay is composed of an integrated circuit. The speed breaks, over -current protection, and three -phase overlapping gates of the hinged route are integrated. This article introduces the principle of combination relay.
更新日期/Last Update: 1900-01-01