[1]陈伟宏、刘方豪、乔泽慧、崔双双.钢筋混凝土框架抗连续倒塌性能影响因素分析[J].郑州大学学报(工学版),2021,42(02):31-37.[doi:10.13705/j.issn.1671-6833.2021.02.007]
 Chen Weihong,Liu Fanghao,Qiao Zehui,et al.Analysis on Factors Affecting the Capability of Collapse of Reinforced Concrete[J].Journal of Zhengzhou University (Engineering Science),2021,42(02):31-37.[doi:10.13705/j.issn.1671-6833.2021.02.007]
点击复制

钢筋混凝土框架抗连续倒塌性能影响因素分析()
分享到:

《郑州大学学报(工学版)》[ISSN:1671-6833/CN:41-1339/T]

卷:
42
期数:
2021年02期
页码:
31-37
栏目:
出版日期:
2021-04-12

文章信息/Info

Title:
Analysis on Factors Affecting the Capability of Collapse of Reinforced Concrete
作者:
陈伟宏、刘方豪、乔泽慧、崔双双
福州大学土木工程学院;福建工程学院土木工程学院;

Author(s):
Chen Weihong; Liu Fanghao; Qiao Zehui; Cui Shuangshuang;
School of Civil Engineering, Fuzhou University; School of Civil Engineering, Fujian Institute of Engineering;

关键词:
Keywords:
DOI:
10.13705/j.issn.1671-6833.2021.02.007
文献标志码:
A
摘要:
钢筋混凝土框架结构在服役期间可能会遭受意外事件作用,造成结构的连续性倒塌。为了研究结构的抗倒塌性能影响因素,首先采用两榀混凝土平面框架抗倒塌试验结果对ABAQUS有限元模型进行了验证与校准。然后基于验证后的模型,建立了15个三层四跨的混凝土平面框架进行不同层数的中柱失效、梁下部钢筋配筋率和梁上部钢筋配筋率等参数的抗倒塌分析。研究表明:当失效柱所在楼层越低,悬链线效应越难发挥作用;梁下部钢筋配筋率的提高对悬链线效应没有正面影响,当配筋率过高时反而会削弱结构的悬链线效应;梁上部钢筋配筋率的提升可以显著增强结构的悬链线效应。悬链效应阶段消耗的能量至少占倒塌全过程消耗总能量的70%,评价结构的鲁棒性时应考虑悬链线效应的作用。
Abstract:
During service, reinforced concrete fr<x>ame structures may suffer from accidents, resulting in the progressive collapse of the structure. Firstly, in order to research on the factors which affect the capability of collapse resistance of the structure, the ABAQUS finite element model was first verified and calibrated by using the progressive collapse test results of the two-la<x>yer concrete plane fr<x>ame Then 15 three-story and four-span concrete plane fr<x>ames were established to carry out the progressive collapse analysis on three parameters ba<x>sed on the verified model. The parameters include the failure of the middle column of the different la<x>yers, the reinforcement ratio at the bottom of the beams, and the reinforcement ratio at the top of the beams. The results show that the lower the floor where the failure of the center column is, the more difficult the catenary action is to play a role. The improvement of the reinforcement ratio at the bottom of the beams has no positive effect on the catenary action. The catenary action of the structure is weakened when the reinforcement ratio is too high. The increase in the reinforcement ratio of the upper part of the beam can significantly enhance the catenary action of the structure. The energy dissipation at the catenary action accounts for at least 70% of the total energy dissipation during the collapse process. Thus, the contribution of the catenary action should be considered when evaluating the structural robustness

相似文献/References:

[1]黄远,王力.考虑扭转作用的 RC 框架抗连续倒塌性能研究[J].郑州大学学报(工学版),2023,44(05):93.[doi:10.13705/j.issn.1671-6833.2023.02.006]
 HUANG Yuan,WANG Li.Progressive Collapse Resistance of RC Frame Structures Considering Torsion[J].Journal of Zhengzhou University (Engineering Science),2023,44(02):93.[doi:10.13705/j.issn.1671-6833.2023.02.006]

更新日期/Last Update: 2021-05-30